Special
Order
Products
LDF
LDF Loudspeaker Master Station with External Control Capability
LDF-20C
LDF-40C
LDF-20CA
LDF-40CA
- LDF SUPPLEMENT TO LAF-C/CA INSTRUCTIONS -
The LDF Loudspeaker Intercom and External Control System is designed for communication between a central master
station and remote intercom stations. The LDF is an expanded feature version of the LAF-C/CA system. All
information regarding installation other than the external control functions is included in the LAF-C/CA instructions. In
addition to communication to remote locations, external devices can be activated, such as activating a CCTV camera
when the associated sub station is selected, selectively controlling the corresponding door strike or maglock, or both.
WIRING DIAGRAM: SYSTEM USED FOR CCTV CAMERA CALL-UP
LS-NVP
Red
LDF-20CA
LS-NVP
Red
1
2
3
LE-DA
1
NOTE:
Leave jumper between E & - on master
and subs when using 2 conductor
homerun wiring IN SINGLE MASTER
SYSTEM ONLY. Jumper BLK/GRN
wires at LS-NVP in 2-wire system.
~
Blk
Grn
Blk
Grn
E
-
20
E
-
External
Terminal Block
CONSTANT CLOSURE:
Normally Open contacts remain closed as
long as master has sub station selected.
RY-PA
#1
1
2
Constant Closure for Station #1
YEL
BLK
RY-PA
#2
Constant Closure for Station #2
YEL
BLK
3
~
20
RY-PA
#3
YEL
Constant Closure for Station #3
BLK
L
PS-1225UL
Terminal Block
DUAL FUNCTIONS FROM EACH CHANNEL:
+
-
+
-
RY-PA
1
BLK
Momentary closure #1
YEL
YEL
#1
Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
RY-PA
#2
Constant closure #1
BLK
L
2 Diodes (1N4001)
RY-PA
#1
2
Momentary
closure #2
YEL
YEL
BLK
LDF Master
RY-PA
#2
Constant
closure #2
Individual Components for System:
BLK
+
-
LDF-nC
Master station with selective contact output capability (20, 40)
Master station w/handset and selective contact output capability (20, 40)
20-call Add-on Selector with selective output capability
40-call Add-on Selector with selective output capability
Relay for selective output (1 per station requiring external contact)
12V DC, 2.5A Power Supply
LDF-nCA
LD-20AS
LD-40AS
RY-PA
PS-1225UL
LE-series
LS-NVP
Any model sub station with LE-prefix
Vandal proof sub station (add SBX-NVP for surface mount)
LDF TERMINAL DEFINITIONS:
+
-
Positive 12V DC input, and constant closure output
Negative
IMPORTANT:
1~40
Station number
1. RY-PA must be used for each additional contact to
isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on separate
terminal block. LDF-40C/CA has two terminal blocks.
E
R
L
Common communication
Occupied LED control
Positive output for selective closure
(Located on terminal block)
Pg. 1
|
3Com Network Router WL 542 User Manual
AG Neovo Flat Panel Television H 17 User Manual
Aiphone Intercom System AN 8050DS User Manual
AKG Acoustics Microphone C 414B TLII User Manual
AMX Switch UDM 0102 User Manual
Audiovox Remote Starter APS 685 User Manual
Bally Refrigerated Boxes Refrigerator Refrigerators Freezers Warmers User Manual
Barco Projector Accessories R9841770 User Manual
Beko Dishwasher DW603 User Manual
Beko Hair Dryer DCU 7430 User Manual